Owner’sOwner’sManualManual

Strany 2 - Table of Contents

Page 7Cautions1. Persons suffering from heart disease, diabetes, high or low blood pres-sure, and any condition requiring medical treatment, pregnant

Strany 3

Page 8Locating Your Sweetwater Hot TubIMPORTANT: Because of the combined weight of the hot tub, water andusers, it is extremely important that the bas

Strany 4 - FCC Notice

Page 9run-off water will shorten the life expectancy of the hot tub cover.* Power cord is not available for Canada - the hot tub must be hard wired.Fo

Strany 5

Page 10Illustration No. 4 240V 4-Wire Hook-upBali Models OnlyIllustration No. 3 120V 3-Wire Hook-upBali Models OnlyIllustration No. 2 240V 3-Wire Hook

Strany 6 - (CSA SAFETY INFORMATION

Page 11Electrical Installation InstructionsFor Connection to 240V Service(Note: The Bali model may be connected to 120V service. See the Instructions

Strany 7 - SAVE THESE INSTRUCTIONS

Page 12Bali 120 VAC Service Connection1. Remove the center cabinet panel directly under the hot tub’s control panel.2. Locate and unroll the GFI prot

Strany 8

BALI DOMESTIC MODEL (60 Hz)**120V/15A 240V/30A * 240V/40A ***Voltage 120 volts 240 volts 240 VoltsCurrent Draw 12 amps 22 amps 28 ampsNo. of Wires Thr

Strany 9 - SAVE THESE INSTRUCTIONS

Page 14Start Up Instructions FOR BEST RESULTS, READ EACH STEP IN ITS ENTIRETY BEFOREPROCEEDING WITH THAT STEP.1. PREPARE THE HOT TUB FOR FILLING• Clea

Strany 10 - Cautions

Page 156. SET HOT TUB TO HEAT (Default Set Temp is 100˚F (38˚C)To warm the hot tub water up to a comfortable temperature, follow these steps:• The LED

Strany 11

Page 16Control PanelsIllustration No. 5BaliDigital Command CenterThese buttons:1. Display temperature setting.2. Change temperature setting.3. Perfor

Strany 12

Table of ContentsImportant Hot Tub Owner Information...1

Strany 13 - Equipment Bay

Page 17WARMER AND COOLER BUTTONSThe hot tub’s thermostat is to provide you with optimum control of the hottub water temperature. This temperature set

Strany 14

Page 18NOTE: Auto Shut-off -- Anytime a pump has been manually turned on,it will automatically turn off after approximately 20 minutes. If at thistim

Strany 15 - * 240V/50A

Page 19To change the filter cycles, press and hold the“WARMER” button and“COOLER” buttons for 3 seconds. This will get you into the filter cycle pro-

Strany 16

Page 20CLEANING THE FILTERYour Sweetwater hot tub is equipped with a cartridge filter located in theskimmer/filter well. Filtering is accomplished whe

Strany 17 - Start Up Instructions

Page 21DRAINING AND REFILLINGCAUTION: There are certain precautions to keep in mind when drain-ing your hot tub. If it is extremely cold, and the hot

Strany 18

Page 22MAINTAINING THE COVERUsing the insulating hot tub cover anytime the hot tub is not in use will sig-nificantly reduce your operating costs, heat

Strany 19 - Control Panels

Page 238. Reinstall the wood side panels and cover the hot tub so that no casualmoisture can enter the hot tub. Disconnect garden hose and replace d

Strany 20 - LIGHT WARMER

Page 24SANITIZINGTo destroy bacteria and organic compounds in the hot tub water, a sanitizermust be used regularly. A residual sanitizer level of 1 t

Strany 21 - Initial Start Up

Page 25SN2 Nonfunctional temperature sensorOpen or short in temperature sensor. Heater is deactivated. This mustbe repaired by the dealer or qualified

Strany 22 - Filter Cycles

Page 26PUMP DOES NOT Depress "Jets" sensor.OPERATE BUT 1. If no sound is detected or if a "buzzing" sound isLIGHT DOES detected, t

Strany 23

Wiring Diagram Bali Domestic (60 Hz)...28Wiring Diagram Cyp

Strany 24

Page 27any comments or suggestions, or if you wish to be informed on any newproducts for your hot tub, please write to us.CONGRATULATIONS on your good

Strany 25

Page 28Electrical Wiring DiagramBali Domestic (60 Hz)NOTE: FOR 240 VOLTS PERMANENTLY CONNECTED UNIT:1. MOVE THE RED WIRE FROM POS. 1 TO POS. 3 ON THE

Strany 26 - Maintaining Water Quality

Page 29OZONATORO3GRNTB1REDWHTREDWHTBLKBLKREDREDREDBLKBLKBLKBLK21HEATER5.5 kWHI - LIMIT / FREEZE SENSORTEMPERATURE SENSORJ1J2J3F120A, 250VSC-20HOT TUB

Strany 27 - Troubleshooting

Page 30OZONATORO3GRNTB1240 VAC, 1 PHASE, 60 HzUSE COPPER CONDUCTORS ONLYWIRE SIZE MUST BE APPROPRIATEPER NEC AND/OR LOCAL CODESREDRED BLKWHTWHTREDBLKB

Strany 28 - Troubleshooting Procedures

Page 31OZONATORO3GRNTB1REDWHTWHTWHTBLKBLKREDREDREDBLKBLKBLKBLK21HEATER2.7 kW @ 230 VACHI - LIMIT / FREEZE SENSORTEMPERATURE SENSORJ1J2J3F120A, 250VSC-

Strany 29

Page 32Electrical Wiring DiagramCyprus and Aruba Export (50 Hz)OZONATORO3GRNTB1NNREDNLL(BRN)NL(BLK)NLLBLKL21HEATER2.7 kW @ 230 VAC17HI - LIMIT / FREEZ

Strany 30

Page 33Electrical Wiring DiagramPalermo and Bahia Export (50 Hz)OZONATORO3GRNTB1230 VAC, 1 PHASE, 50 HzUSE COPPER CONDUCTORS ONLYWIRE SIZE MUST BE APP

Strany 31 - Bali Domestic (60 Hz)

14525 Monte Vista Ave, Chino, CA 91710/USAPart #6530-320 • Rev. D • © 2001 Sundance Spas, Inc.

Strany 32

Page 1Important Hot Tub Owner InformationYour Sweetwater hot tub is constructed to the highest stan-dards and is capable of providing many years of tr

Strany 33

Page 2IMPORTANT SAFETY INSTRUCTIONS:READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYWhen installing and using this electrical equipment, basic safety preca

Strany 34 - Bali Export (50 Hz)

Page 38) WARNING: To Reduce the Risk of Injury:a) The water in a hot tub should never exceed 104˚F (40˚C). Water tem-peratures between 100˚F (38˚C) an

Strany 35

Page 4c) At least two lugs marked “Bonding Lugs” are provided on the externalsurface or on the inside of the supply terminal box/compartment. Toreduce

Strany 36

Page 5AVERTISSEMENT: POUR EVITER L’EVANOUISSEMENT ET LA NOYADEEVENTUELLE, NE PRENDRE NI DROGUE NI ALCOOL AVANT D’UTILISER LACUVE DE RELAXATION NI QUAN

Strany 37

Page 6CAUTION: Maintain water chemistry in accordance with manufacturer’sinstructions.AT TENTION: LA TENEUR DE L’EAU EN MATIERES DISSOUTES DOIT ETRECO